TRC-00789 | TIMP-3 (Human) ELISA Kit | 96 Well
Product Overview
A Sandwich ELISA kit for the quantitative measurement of human TIMP-3 in serum, plasma and other biological
TIMP-3 belongs to the TIMP gene family. The proteins encoded by this gene family are inhibitors of the matrix metalloproteinases, a group of peptidases involved in degradation of the extracellular matrix (ECM). Expression of this gene is induced in response to mitogenic stimulation and this netrin domain-containing protein is localized to the ECM. Mutations in this gene have been associated with the autosomal dominant disorder Sorsby's fundus dystrophy. 96Trace’s TIMP-3 (Human) ELISA Kit is based on the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human TIMP-3. Standards or samples are added to the micro ELISA plate wells that bind to the specific antibody. Then a biotinylated detection antibody specific for Human TIMP-3 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. The wells are washed, a TMB substrate solution is added to the wells and blue color develops in proportion to the amount of TIMP-3 bound. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of Human TIMP-3. The concentration of Human TIMP-3 in the samples can be calculated by comparing the OD of the samples to the standard curve.
Assay Information
| Assay Format | Sandwich ELISA |
| Species Reactivity | Human |
| Sample Type | Plasma,Serum,Other biological fluids |
| Detection Method | Sandwich ELISA, Absorbance (450 nm) |
| Detection Wavelength | 450 nm |
| Kit Size | 96 Well |
Performance Data
| Detection Range | 62.50-4000 pg/mL,Sensitivity: 37.50 pg/mL,Precision: Coefficient of variation is < |
| Sensitivity | 37.50 pg/mL,Precision: Coefficient of variation is < |
Applications
in-vitro quantitative determination of Human TIMP-3 concentrations in serum, plasma and other biological fluids.
Features & Benefits
Specificity: No Significant cross-reactivity or interference between Human TIMP-3 and analogues was observed,Detection Range: 62.50-4000 pg/mL,Sensitivity: 37.50 pg/mL,Precision: Coefficient of variation is < 10%.
Storage & Shipping
| Storage | +4°C |
| Shipping | Gel Pack |
| Shelf Life | 6 Months |
Product Details
| 96Trace CAT | E4842-100 |
| Supplier CAT | TRC-00789 |
| Analyte / Target | TIMP-3 |
| Category | Cardiovascular ELISA Kits |
| Alternate Name | Metalloproteinase inhibitor 3, Protein MIG-5, Tissue inhibitor of metalloproteinases 3, TIMP-3 |